1. Summary
2. Block Diagram
3. Technical Parameters
* Special Notice:
The performance parameters of this manual according to GY/T 194-2003 <CATV system optical workstation technical requirements and methods of measurement> .We get it under the following testing environment.
* Testing Environment:
1.Down optical receiver part :Together with Standard 1550nm External Modulation Optical Transmitter,10km standard optical fiber and optical passive attenuator make the testing circuit .Set with 59 PAL-D analog TV channel signal at range of 47 MHZ ~550MHZ in the fix index loss of circuit, transmit digital TV signal at rang of 550MHZ~862MHZ ,the electricity(8 MHZ bandwidth) digital signal is 10dB lower than analog signal of carrier electricity level. When the input of optical receiver is -1dBm, RF output lever is 104 dBμV , measure C/CTB,C/CSO,C/N.
2. Uplink optical transmitter part: Link Flatness and noise Power Ratio (NPR) dynamic range are circuit index made up by uplink optical transmitter and uplink optical receiver.
★Tips:
The RF signal should be set to be 9~12dB incline output in practical engineering applications for suggestion in order to improve nonlinear index of cable transmission system under optical contactor.
4. Optional Options
Option1: Network Management Module
Option2: Network Management Transponder
Option3: Optical receiver backup module
Option4: Return optical transmitter module (FP laser with isolator are recommended)
Option5: Switching power supply hot backup module
5. Ordering Guide
The defaulted configuration is two-way provided configuration (One optical receiver module and one switching power supply module);If you need others, please tell us with the downlink, uplink division frequency of two-way channel when ordering.
|
Items |
Unit |
Technical Parameters |
||
|
|
|
WR8604HC |
||
|
Forward Path |
||||
|
Optical Parameters |
||||
|
Received Optical Wavelength |
nm |
1100 ~ 1600 |
||
|
Received Optical Power Range |
dBm |
-9 ~ +2 |
||
|
Recommended Range |
dBm |
-3 ~ +1 |
||
|
Optical Fiber Type |
Single-mode |
|||
|
Optical Fiber Connector Type |
FC/APC或SC/APC |
|||
|
Optical Return Loss |
dB |
> 45 |
||
|
Link Parameters |
||||
|
C/N |
dB |
≥ 51 |
||
|
C/CTB |
dB |
≥ 65 |
||
|
C/CSO |
dB |
≥ 60 |
||
|
RF Parameters |
||||
|
Frequency Range |
MHz |
45/87 ~750/862 |
||
|
Flatness in Band |
dB |
±0.75 |
||
|
Nominal Output Level |
dBμV |
≥108 |
||
|
Max Output Lever |
dBμV |
≥ 112 |
||
|
Output Return Loss |
dB |
≥16(45~550 MHz);≥14(550~862 MHz) |
||
|
Output Impedance |
Ω |
75 |
||
|
Return Path |
||||
|
Optical Parameters |
||||
|
Optical Emission Wavelength |
nm |
1310±10 |
||
|
Laser Type |
FP or DFB |
|||
|
Output Optical Power |
mW |
1 ~3 |
||
|
Optical Connector Type |
FC/APC、SC/APC (It is up to users) |
|||
|
RF Parameters |
||||
|
Frequency Range |
MHz |
5 ~ 30/65 (It is up to users) |
||
|
Link Flatness |
dB |
±1.5 |
||
|
Input Level |
dBμV |
75 ~ 85 |
||
|
Input Return Loss |
dB |
≥16 |
||
|
Output Impedance |
Ω |
75 |
||
|
NPR Dynamic Range |
dB |
≥10(NPR≥30 dB) |
||
|
General Characteristics |
||||
|
Supply Voltage |
V |
AC 135~250(50 Hz)或AC 35 ~ 90 (50 Hz) |
||
|
Power Consumption |
W |
≤70 |
||
|
Operating Temperature |
℃ |
-30 ~ +70 |
||
|
Storage Temperature |
℃ |
-30 ~ +70 |
||
|
Relative Humidity |
% |
Maximum 95% non-condensing |
||
|
Dimension |
mm |
430(L)* 250(W)* 160(H) |
||
Cách đặt hàng tại C-Link:
1. Hotline: 0904.999.815
2. Email: info@c-link.vn
3. Trực tiếp: Số 207, ngõ 192 Lê Trọng Tấn, Định Công, Hoàng Mai, Hà Nội