The UT-N201 has to be installed by authorized professional person, to avoid incorrect installation or application to influence the normal working and lightning protection of devices, used in over-voltage protection from lightning and EMP of network equipments, like SWITCH, HUB, ROUTER, etc
Model
|
UT-N101
|
UT-N201
|
Rated operating voltage (Un)
|
5 V
|
5 V
|
Max. DC operating voltage (Uc)
|
6 V
|
6 V
|
Max. AC operating voltage (Uc)
|
4.2 V
|
4.2 V
|
Nominal operating current (IL)
|
0.12 A
|
0.12 A
|
Nominal discharge current (8/20 us) (In)
|
3 KA
|
5 KA
|
Maximum discharge current (In)
|
5 KA
|
10 KA
|
Limiting voltage (Upl)
|
≤12 V
|
≤12 V
|
Series impedance characteristic of wire (Ro)
|
10 Ohm
|
10 Ohm
|
Wire-to-wire capacitance (Cll)
|
≤3 pF
|
≤3 pF
|
Wire-to-earth capacitance (Cpe)
|
≤3 pF
|
≤3 pF
|
Response time (ta)
|
<1 ns
|
<1 ns
|
Range of operating temperature
|
-40℃ ~ 85℃
|
-40℃ ~85℃
|
Testing standard
|
IEC61000-4-5
|
IEC61000-4-5
|
Testing level
|
X
|
X
|
Insulation resistance
|
>1 MΩ
|
>1 MΩ
|
Insertion loss (dB)
|
≤0.5 dB
|
≤0.5 dB
|
Enclosure protection class
|
IP30
|
IP30
|
Overall dimension
|
25 x 40 x 75
|
25 x 40 x 75
|
Enclosure material
|
Shielded metallic aluminum
|
Shielded metallic aluminum
|
Type of wiring
|
Connection terminal (RJ45)
|
Connection terminal (RJ45)
|
Protection pairs
|
2 pairs (1-2, 3-6)
|
2 pairs (1-2, 3-6)
|
Anti-static level
|
Class 4
|
Class 4
|
Transmission rate (bps)
|
500 M
|
500 M
|
Operating Environment
Temperature: -40°C ~ 85°C;
Relative humidity: 5% ~ 95%;
Barometric pressure: 70 kPa ~ 106 kPa